<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Vacuum Gauge &#8211; Instrumentation-Electronics</title>
	<atom:link href="http://www.instrumentationtoday.com/tag/vacuum-gauge/feed/" rel="self" type="application/rss+xml" />
	<link>http://www.instrumentationtoday.com</link>
	<description>All About Electronics Instrumentation</description>
	<lastBuildDate>Mon, 21 Jan 2013 09:42:06 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>https://wordpress.org/?v=5.0.13</generator>
	<item>
		<title>Ionization Gauge &#8211; Cold Cathode Type</title>
		<link>http://www.instrumentationtoday.com/ionization-gauge-cold-cathode-type/2012/01/</link>
		<comments>http://www.instrumentationtoday.com/ionization-gauge-cold-cathode-type/2012/01/#respond</comments>
		<pubDate>Tue, 10 Jan 2012 06:15:10 +0000</pubDate>
		<dc:creator><![CDATA[John]]></dc:creator>
				<category><![CDATA[Transducers]]></category>
		<category><![CDATA[Sensors]]></category>
		<category><![CDATA[Vacuum Gauge]]></category>

		<guid isPermaLink="false">http://www.instrumentationtoday.com/?p=587</guid>
		<description><![CDATA[<p>The cold cathode type ionization gauge is used to replace the hot cathode type, as it produces errors at very high temperatures of the cathode. To overcome this problem, the electrodes must be roperly treated before use. All these problems can be nullified by vacuum measurement using cold cathode ionization gauge. A Philips and Penning [&#8230;]</p>
<p>The post <a rel="nofollow" href="http://www.instrumentationtoday.com/ionization-gauge-cold-cathode-type/2012/01/">Ionization Gauge &#8211; Cold Cathode Type</a> appeared first on <a rel="nofollow" href="http://www.instrumentationtoday.com">Instrumentation-Electronics</a>.</p>
]]></description>
				<content:encoded><![CDATA[<p style="text-align: justify;">The cold cathode type ionization gauge is used to replace the <a title="Hot Cathode Type Ionization Gauge" href="http://www.instrumentationtoday.com/ionization-gauge-hot-cathode-type/2012/01/" target="_blank"><span style="text-decoration: underline;"><strong>hot cathode type</strong></span></a>, as it produces errors at very high temperatures of the cathode. To overcome this problem, the electrodes must be roperly treated before use. All these problems can be nullified by <a title="Vacuum Gauge" href="http://www.instrumentationtoday.com/vacuum-gauge/2011/10/" target="_blank"><span style="text-decoration: underline;"><strong>vacuum measurement</strong></span></a> using cold cathode ionization gauge.</p>
<p style="text-align: justify;">A Philips and Penning cold cathode gauge is shown below. The device consists of two cathodes and a hollow anode in between. An input voltage greater than 2 Kilovolt is applied between them. A strong magnetic field is produced due to the applied voltage and thus the electrons are ejected. This causes the gauge to operate. At pressures below 10<sup>-2</sup> Torr, the mean free path of the gas is so large that a collision may not occur at all so that discharge is not sustained or ionization may not be initiated. This problem can be eliminated by a collimating magnetic field. This is shown in the figure below.</p>
<div class="mceTemp" style="text-align: justify;">
<dl id="attachment_681" class="wp-caption alignnone" style="width: 535px;">
<dt class="wp-caption-dt"><a href="http://www.instrumentationtoday.com/wp-content/uploads/2012/01/Ionization-Gauge-Cold-Cathode-Type.jpg"><img class="size-full wp-image-681" title="Ionization Gauge - Cold Cathode Type" src="http://www.instrumentationtoday.com/wp-content/uploads/2012/01/Ionization-Gauge-Cold-Cathode-Type.jpg" alt="Ionization Gauge - Cold Cathode Type" width="525" height="385" srcset="http://www.instrumentationtoday.com/wp-content/uploads/2012/01/Ionization-Gauge-Cold-Cathode-Type.jpg 525w, http://www.instrumentationtoday.com/wp-content/uploads/2012/01/Ionization-Gauge-Cold-Cathode-Type-300x220.jpg 300w, http://www.instrumentationtoday.com/wp-content/uploads/2012/01/Ionization-Gauge-Cold-Cathode-Type-409x300.jpg 409w" sizes="(max-width: 525px) 100vw, 525px" /></a></dt>
<dd class="wp-caption-dd">                              Ionization Gauge &#8211; Cold Cathode Type</dd>
</dl>
</div>
<p style="text-align: justify;">The collimating magnetic field increases the path length for the electrons, enabling discharges possible at pressures down to about 10<sup>-5</sup> Torr. It is difficult to obtain linearity between the meter reading and pressure as there occurs interactions between the positive ions and electrons at high electric and magnetic fields.</p>
<p>The post <a rel="nofollow" href="http://www.instrumentationtoday.com/ionization-gauge-cold-cathode-type/2012/01/">Ionization Gauge &#8211; Cold Cathode Type</a> appeared first on <a rel="nofollow" href="http://www.instrumentationtoday.com">Instrumentation-Electronics</a>.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.instrumentationtoday.com/ionization-gauge-cold-cathode-type/2012/01/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Ionization Gauge &#8211; Hot Cathode Type</title>
		<link>http://www.instrumentationtoday.com/ionization-gauge-hot-cathode-type/2012/01/</link>
		<comments>http://www.instrumentationtoday.com/ionization-gauge-hot-cathode-type/2012/01/#comments</comments>
		<pubDate>Tue, 10 Jan 2012 06:07:11 +0000</pubDate>
		<dc:creator><![CDATA[John]]></dc:creator>
				<category><![CDATA[Transducers]]></category>
		<category><![CDATA[Sensors]]></category>
		<category><![CDATA[Vacuum Gauge]]></category>

		<guid isPermaLink="false">http://www.instrumentationtoday.com/?p=585</guid>
		<description><![CDATA[<p>Ionization Gauge is a device that is used to measure vacuum. In the hot cathode type, a column of gas is introduced into which, a potential difference V is applied with free electron in the space. This causes the electron with a charge e to acquire a kinetic energy Ve. If the pressure range of [&#8230;]</p>
<p>The post <a rel="nofollow" href="http://www.instrumentationtoday.com/ionization-gauge-hot-cathode-type/2012/01/">Ionization Gauge &#8211; Hot Cathode Type</a> appeared first on <a rel="nofollow" href="http://www.instrumentationtoday.com">Instrumentation-Electronics</a>.</p>
]]></description>
				<content:encoded><![CDATA[<p style="text-align: justify;">Ionization Gauge is a device that is used to <strong><span style="text-decoration: underline;"><a href="../vacuum-gauge/2011/10/">measure vacuum</a></span></strong>. In the hot cathode type, a column of gas is introduced into which, a potential difference V is applied with free electron in the space. This causes the electron with a charge e to acquire a kinetic energy Ve. If the pressure range of the gas in the column goes below a certain limit, called the critical pressure, then corresponding to a voltage larger than the critical voltage Vc, the energy Ve may be high enough to initiate ionization, and positive ions will be produced when the electrons collide with the gas molecules.</p>
<p style="text-align: justify;">The value of Vc is smallest for cesium (3.88V) and largest for helium (24.58V), among monoatomic gases or vapours. For diatomic gases like N2, H2 and so on, it is roughly about 15V. This is known as the ionization potential and at this potential the pressure is also important.</p>
<p style="text-align: justify;">At very low pressures, during the intervals of time for transit from the cathode to the plate in a vacuum chamber, more than one collision is unlikely for an electron. Then for a fixed accelerating potential V&gt;Vc, the number of positive ions formed would vary linearly with the value of pressure. Thus, a determination of the rate of production of positive ions for a given electron current should give a measure of the pressure.</p>
<p style="text-align: justify;"><strong>Working</strong></p>
<p style="text-align: justify;">The construction of a hot cathode type ionization gauge consists of a basic vacuum triode. The figure of an external control type hot cathode gauge is shown below.</p>
<div class="mceTemp" style="text-align: justify;">
<dl id="attachment_677" class="wp-caption alignnone" style="width: 381px;">
<dt class="wp-caption-dt"><a href="http://www.instrumentationtoday.com/wp-content/uploads/2012/01/External-Type-Ionisation-Gauge.jpg"><img class="size-full wp-image-677" title="External Type Ionisation Gauge" src="http://www.instrumentationtoday.com/wp-content/uploads/2012/01/External-Type-Ionisation-Gauge.jpg" alt="External Type Ionisation Gauge" width="371" height="412" srcset="http://www.instrumentationtoday.com/wp-content/uploads/2012/01/External-Type-Ionisation-Gauge.jpg 371w, http://www.instrumentationtoday.com/wp-content/uploads/2012/01/External-Type-Ionisation-Gauge-270x300.jpg 270w" sizes="(max-width: 371px) 100vw, 371px" /></a></dt>
<dd class="wp-caption-dd">                   External Type Ionisation Gauge</dd>
</dl>
</div>
<p style="text-align: justify;">The grid is maintained at a large positive potential with respect to the cathode and the plate. The plate is at a negative potential with respect to the cathode. This method is also known as the external control type ionization gauge as the positive ion collector is external to the electron collector grid with reference to the cathode. The positive ions available between the grid and the cathode will be drawn by the cathode, and those between the grid and the plate will be collected by the plate.</p>
<p style="text-align: justify;">The internal control type is shown below. Here the grid is the positive ion collector and the plate is the electron collector.</p>
<div class="mceTemp" style="text-align: justify;">
<dl id="attachment_678" class="wp-caption alignnone" style="width: 375px;">
<dt class="wp-caption-dt"><a href="http://www.instrumentationtoday.com/wp-content/uploads/2012/01/Internal-Type-Ionisation-Gauge.jpg"><img class="size-full wp-image-678" title="Internal Type Ionisation Gauge" src="http://www.instrumentationtoday.com/wp-content/uploads/2012/01/Internal-Type-Ionisation-Gauge.jpg" alt="Internal Type Ionisation Gauge" width="365" height="416" srcset="http://www.instrumentationtoday.com/wp-content/uploads/2012/01/Internal-Type-Ionisation-Gauge.jpg 365w, http://www.instrumentationtoday.com/wp-content/uploads/2012/01/Internal-Type-Ionisation-Gauge-263x300.jpg 263w" sizes="(max-width: 365px) 100vw, 365px" /></a></dt>
<dd class="wp-caption-dd">Internal Type Ionisation Gauge</dd>
</dl>
</div>
<p style="text-align: justify;">One of the most popularly used hot filament gauges for industrial applications is the Bayard – Alpert type filament gauge. It consists of a helical grid with a potential of +150 volts. This huge potential attracts the electrons and thus causes gas ionization. At -30 volts, the gas ions are attracted to the central ion collector, thus producing an ion current of 100mA/Torr. This value is then fed to the electronic systems to be amplified and displayed.</p>
<p style="text-align: justify;">The hot cathode ionization gauge is useful in measuring the total pressure of all the gases present in the system. The biggest advantage of this device is its very small response time. This is because of the devices small inertia. The device is used for pressure measurement between the ranges of 10<sup>-8 </sup>to 10<sup>-3 </sup>Torr with an output current varying between 10<sup>-9</sup> to 10<sup>-4</sup> A.  But this range depends on the gas, other things remaining constant.</p>
<p style="text-align: justify;">Where the pressure is higher than 10<sup>-3</sup> Torr, the positive ions make a greater impact on the cathode to heat it up and ultimately destroy it. At pressure ranges below 10<sup>-8</sup> Torr, in external control type, the electrons impact over the grid and radiates soft x-rays, which results in the production of electrons from the plates as secondary emission. These electrons produced will be of the same order as that of the positive ion current in the plate circuit and thus neutralizes this current. Thus the internal control type is known to be a better option to measure pressure as low as 10<sup>-9 </sup>Torr.</p>
<p style="text-align: justify;">When the cathode remains at very temperatures (say 3000 deg C), the gaseous matters present inside may reset with the filament or with themselves particularly at different pressure stages. This may causes the device to produce wrong outputs and may also affect the cathode life. During extreme conditions of high temperatures and low pressures, the presence of any gases inside the device, will be forcefully released, thus causing the pressure to increase. Thus, the electrodes have to be properly treated before use. This can be done only by passing high currents through the electrodes, especially the filament and the grid and by high frequency heating of the plate. To overcome these problems, the <a title="Cold Cathode Type Ionization Gauge " href="http://www.instrumentationtoday.com/ionization-gauge-cold-cathode-type/2012/01/" target="_blank"><strong><span style="text-decoration: underline;">cold cathode type ionization gauge</span></strong></a> is also used by many.</p>
<p>The post <a rel="nofollow" href="http://www.instrumentationtoday.com/ionization-gauge-hot-cathode-type/2012/01/">Ionization Gauge &#8211; Hot Cathode Type</a> appeared first on <a rel="nofollow" href="http://www.instrumentationtoday.com">Instrumentation-Electronics</a>.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.instrumentationtoday.com/ionization-gauge-hot-cathode-type/2012/01/feed/</wfw:commentRss>
		<slash:comments>1</slash:comments>
		</item>
		<item>
		<title>Alphatron Vacuum Gauge</title>
		<link>http://www.instrumentationtoday.com/alphatron-vacuum-gauge/2011/10/</link>
		<comments>http://www.instrumentationtoday.com/alphatron-vacuum-gauge/2011/10/#comments</comments>
		<pubDate>Fri, 07 Oct 2011 09:00:53 +0000</pubDate>
		<dc:creator><![CDATA[John]]></dc:creator>
				<category><![CDATA[Transducers]]></category>
		<category><![CDATA[Sensors]]></category>
		<category><![CDATA[Vacuum Gauge]]></category>

		<guid isPermaLink="false">http://www.instrumentationtoday.com/?p=589</guid>
		<description><![CDATA[<p>Alphatron is a type of cold cathode ionization gauge and can also be considered as a radioactive ionization gauge. As the cold cathode and hot cathode types earlier explained, are composition dependent, the transfer characteristics may be obtained relative to air for different gases and the system can be used as a leak detector. You [&#8230;]</p>
<p>The post <a rel="nofollow" href="http://www.instrumentationtoday.com/alphatron-vacuum-gauge/2011/10/">Alphatron Vacuum Gauge</a> appeared first on <a rel="nofollow" href="http://www.instrumentationtoday.com">Instrumentation-Electronics</a>.</p>
]]></description>
				<content:encoded><![CDATA[<p style="text-align: justify;">Alphatron is a type of <a title="Ionization Gauge – Cold Cathode Type" href="http://www.instrumentationtoday.com/ionization-gauge-cold-cathode-type/2012/01/" target="_blank"><strong><span style="text-decoration: underline;">cold cathode ionization gauge</span></strong></a> and can also be considered as a radioactive ionization gauge. As the cold cathode and <a title="Ionization Gauge – Hot Cathode Type" href="http://www.instrumentationtoday.com/ionization-gauge-hot-cathode-type/2012/01/" target="_blank"><strong><span style="text-decoration: underline;">hot cathode</span></strong></a> types earlier explained, are composition dependent, the transfer characteristics may be obtained relative to air for different gases and the system can be used as a leak detector.</p>
<p style="text-align: justify;">You may also like: <a title="Vacuum Gauge" href="http://www.instrumentationtoday.com/vacuum-gauge/2011/10/" target="_blank"><strong><span style="text-decoration: underline;">Vacuum Gauge</span></strong></a> and <a title="Pressure Transducer" href="http://www.instrumentationtoday.com/pressure-transducer/2011/09/" target="_blank"><strong><span style="text-decoration: underline;">Pressure Sensors</span></strong></a></p>
<p style="text-align: justify;">The device uses alpha particles in order to ionize the gas in the vacuum chamber. The number of ions formed in the chamber is directly proportional to the gas pressure, if the chamber dimensions are shorter than the range of alpha particles. The figure below shows the schematic diagram of an alphatron.</p>
<div id="attachment_646" style="width: 413px" class="wp-caption alignnone"><a href="http://www.instrumentationtoday.com/wp-content/uploads/2011/10/Alphatron-Vacuum-Gauge.jpg"><img class="size-full wp-image-646" title="Alphatron Vacuum Gauge" src="http://www.instrumentationtoday.com/wp-content/uploads/2011/10/Alphatron-Vacuum-Gauge.jpg" alt="Alphatron Vacuum Gauge" width="403" height="316" srcset="http://www.instrumentationtoday.com/wp-content/uploads/2011/10/Alphatron-Vacuum-Gauge.jpg 403w, http://www.instrumentationtoday.com/wp-content/uploads/2011/10/Alphatron-Vacuum-Gauge-300x235.jpg 300w, http://www.instrumentationtoday.com/wp-content/uploads/2011/10/Alphatron-Vacuum-Gauge-382x300.jpg 382w" sizes="(max-width: 403px) 100vw, 403px" /></a><p class="wp-caption-text">Alphatron Vacuum Gauge</p></div>
<p style="text-align: justify;">The ions produced by the alpha particles are collected by the collector electrode and a current between 10<sup>-13</sup> and 10<sup>-9</sup> Amperes will flow though the resistor R. The output voltage e0 is measured using a high input impedance output meter. The device has a range between 10<sup>3</sup> to 10<sup>-3</sup> Torr.</p>
<p>The post <a rel="nofollow" href="http://www.instrumentationtoday.com/alphatron-vacuum-gauge/2011/10/">Alphatron Vacuum Gauge</a> appeared first on <a rel="nofollow" href="http://www.instrumentationtoday.com">Instrumentation-Electronics</a>.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.instrumentationtoday.com/alphatron-vacuum-gauge/2011/10/feed/</wfw:commentRss>
		<slash:comments>1</slash:comments>
		</item>
		<item>
		<title>Quartz Reference Vacuum Gauge</title>
		<link>http://www.instrumentationtoday.com/quartz-reference-vacuum-gauge/2011/10/</link>
		<comments>http://www.instrumentationtoday.com/quartz-reference-vacuum-gauge/2011/10/#respond</comments>
		<pubDate>Fri, 07 Oct 2011 08:57:59 +0000</pubDate>
		<dc:creator><![CDATA[John]]></dc:creator>
				<category><![CDATA[Transducers]]></category>
		<category><![CDATA[Sensors]]></category>
		<category><![CDATA[Vacuum Gauge]]></category>

		<guid isPermaLink="false">http://www.instrumentationtoday.com/?p=591</guid>
		<description><![CDATA[<p>A quartz reference gauge is a device used to measure vacuum. The working principle is pretty much same to that of a bourdon tube. Here, 2 bourdon tubes are used and a formed into a helix. When a pressure difference between the two occurs, the setup begins to rotate. This rotational deflection is picked up [&#8230;]</p>
<p>The post <a rel="nofollow" href="http://www.instrumentationtoday.com/quartz-reference-vacuum-gauge/2011/10/">Quartz Reference Vacuum Gauge</a> appeared first on <a rel="nofollow" href="http://www.instrumentationtoday.com">Instrumentation-Electronics</a>.</p>
]]></description>
				<content:encoded><![CDATA[<p style="text-align: justify;">A quartz reference gauge is a device used to <a title="Vacuum Gauge" href="http://www.instrumentationtoday.com/vacuum-gauge/2011/10/" target="_blank"><strong><span style="text-decoration: underline;">measure vacuum</span></strong></a>. The working principle is pretty much same to that of a bourdon tube. Here, 2 bourdon tubes are used and a formed into a helix. When a pressure difference between the two occurs, the setup begins to rotate. This rotational deflection is picked up using an optical circuit as show in the figure below.</p>
<p style="text-align: justify;">You may also like this: <a title="Pressure Transducer" href="http://www.instrumentationtoday.com/pressure-transducer/2011/09/" target="_blank"><strong><span style="text-decoration: underline;">Pressure Sensors</span></strong></a></p>
<div class="mceTemp" style="text-align: justify;">
<dl id="attachment_643" class="wp-caption alignnone" style="width: 628px;">
<dt class="wp-caption-dt"><a href="http://www.instrumentationtoday.com/wp-content/uploads/2011/10/Quartz-Reference-Vacuum-Gauge.jpg"><img class="size-full wp-image-643" title="Quartz Reference Vacuum Gauge" src="http://www.instrumentationtoday.com/wp-content/uploads/2011/10/Quartz-Reference-Vacuum-Gauge.jpg" alt="Quartz Reference Vacuum Gauge" width="618" height="377" srcset="http://www.instrumentationtoday.com/wp-content/uploads/2011/10/Quartz-Reference-Vacuum-Gauge.jpg 618w, http://www.instrumentationtoday.com/wp-content/uploads/2011/10/Quartz-Reference-Vacuum-Gauge-300x183.jpg 300w, http://www.instrumentationtoday.com/wp-content/uploads/2011/10/Quartz-Reference-Vacuum-Gauge-491x300.jpg 491w" sizes="(max-width: 618px) 100vw, 618px" /></a></dt>
<dd class="wp-caption-dd">                                     Quartz Reference Vacuum Gauge</dd>
</dl>
</div>
<p style="text-align: justify;">The reason for using quartz is that it has good spring characteristics and if the unit is kept at a constant temperature environment, the angular deflection per unit pressure is repeatable. The main disadvantage with the device is that it cannot be used as a vacuum gauge in gases with fluorine content as this erodes quartz.</p>
<p style="text-align: justify;">The rotational deflection is connected into an electronic signal, after it passes through the optical circuit. This electronic circuit is further amplified and then the output is annulled using a servo-control system. The corresponding output is displayed by analogue techniques or counted digitally, which can be directly in pressure units. With a tachogenerator on the servomotor shaft a damping adjustment facility can be provided, if necessary. The device is known to have a resolution of 1 milliTorr for 100 milliTorr full scale reading.</p>
<p>The post <a rel="nofollow" href="http://www.instrumentationtoday.com/quartz-reference-vacuum-gauge/2011/10/">Quartz Reference Vacuum Gauge</a> appeared first on <a rel="nofollow" href="http://www.instrumentationtoday.com">Instrumentation-Electronics</a>.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.instrumentationtoday.com/quartz-reference-vacuum-gauge/2011/10/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Thermocouple Vacuum Gauge</title>
		<link>http://www.instrumentationtoday.com/thermocouple-vacuum-gauge/2011/10/</link>
		<comments>http://www.instrumentationtoday.com/thermocouple-vacuum-gauge/2011/10/#comments</comments>
		<pubDate>Wed, 05 Oct 2011 05:39:52 +0000</pubDate>
		<dc:creator><![CDATA[John]]></dc:creator>
				<category><![CDATA[Transducers]]></category>
		<category><![CDATA[Sensors]]></category>
		<category><![CDATA[Vacuum Gauge]]></category>

		<guid isPermaLink="false">http://www.instrumentationtoday.com/?p=583</guid>
		<description><![CDATA[<p>The working of a thermocouple type vacuum gauge is very similar to that of a pirani gauge. The only difference is that the hot wire temperature is measured directly with a thermocouple which is attached to a wire. For different pressures, the temperature is measured by the fine-wire thermocouple, the hating current being initially fixed [&#8230;]</p>
<p>The post <a rel="nofollow" href="http://www.instrumentationtoday.com/thermocouple-vacuum-gauge/2011/10/">Thermocouple Vacuum Gauge</a> appeared first on <a rel="nofollow" href="http://www.instrumentationtoday.com">Instrumentation-Electronics</a>.</p>
]]></description>
				<content:encoded><![CDATA[<p style="text-align: justify;">The working of a thermocouple type vacuum gauge is very similar to that of a <a title="Pirani Gauge" href="http://www.instrumentationtoday.com/pirani-gauge/2011/10/" target="_blank"><strong><span style="text-decoration: underline;">pirani gauge</span></strong></a>. The only difference is that the hot wire temperature is measured directly with a <a title="Thermocouple" href="http://www.instrumentationtoday.com/thermocouple/2011/08/" target="_blank"><strong><span style="text-decoration: underline;">thermocouple</span></strong></a> which is attached to a wire. For different pressures, the temperature is measured by the fine-wire thermocouple, the hating current being initially fixed by the resistance as shown in the figure. This device is usually used for comparison purposes. The sensitivity of such an instrument depends on the pressure and the wire current.</p>
<div class="mceTemp" style="text-align: justify;">
<dl id="attachment_640" class="wp-caption alignnone" style="width: 434px;">
<dt class="wp-caption-dt"><a href="http://www.instrumentationtoday.com/wp-content/uploads/2011/10/Thermocouple-Type-Vacuum-Gauge.jpg"><img class="size-full wp-image-640" title="Thermocouple Type Vacuum Gauge" src="http://www.instrumentationtoday.com/wp-content/uploads/2011/10/Thermocouple-Type-Vacuum-Gauge.jpg" alt="Thermocouple Type Vacuum Gauge" width="424" height="433" srcset="http://www.instrumentationtoday.com/wp-content/uploads/2011/10/Thermocouple-Type-Vacuum-Gauge.jpg 424w, http://www.instrumentationtoday.com/wp-content/uploads/2011/10/Thermocouple-Type-Vacuum-Gauge-293x300.jpg 293w" sizes="(max-width: 424px) 100vw, 424px" /></a></dt>
<dd class="wp-caption-dd">                        Thermocouple Type Vacuum Gauge</dd>
</dl>
</div>
<p style="text-align: justify;">You may also like: <a title="Vacuum Gauge" href="http://www.instrumentationtoday.com/vacuum-gauge/2011/10/" target="_blank"><strong><span style="text-decoration: underline;">Vacuum Gauges</span></strong></a> and <a title="Pressure Transducer" href="http://www.instrumentationtoday.com/pressure-transducer/2011/09/" target="_blank"><strong><span style="text-decoration: underline;">Pressure Sensors</span></strong></a></p>
<p style="text-align: justify;">The figure below shows the working of thermocouple gauges for comparison purposes. Two sets of thermocouples are used to measure temperatures of heater wires in the two chambers and oppose each other. When there is a difference in pressures, there occurs an unbalance which is measured by a potentiometer circuit. Instead of a single thermocouple per wire, a <a title="Thermopile" href="http://www.instrumentationtoday.com/thermocouple/2011/08/#thermopile" target="_blank"><strong><span style="text-decoration: underline;">thermopile</span></strong></a> is often chosen to increase sensitivity. The thermocouple gauge is also composition dependent and needs empirical calibration for the high vacuum range.</p>
<div class="mceTemp" style="text-align: justify;">
<dl id="attachment_641" class="wp-caption alignnone" style="width: 515px;">
<dt class="wp-caption-dt"><a href="http://www.instrumentationtoday.com/wp-content/uploads/2011/10/Vacuum-Comparison-by-Thermocouple-Gauges.jpg"><img class="size-full wp-image-641" title="Vacuum Comparison by Thermocouple Gauges" src="http://www.instrumentationtoday.com/wp-content/uploads/2011/10/Vacuum-Comparison-by-Thermocouple-Gauges.jpg" alt="Vacuum Comparison by Thermocouple Gauges" width="505" height="364" srcset="http://www.instrumentationtoday.com/wp-content/uploads/2011/10/Vacuum-Comparison-by-Thermocouple-Gauges.jpg 505w, http://www.instrumentationtoday.com/wp-content/uploads/2011/10/Vacuum-Comparison-by-Thermocouple-Gauges-300x216.jpg 300w, http://www.instrumentationtoday.com/wp-content/uploads/2011/10/Vacuum-Comparison-by-Thermocouple-Gauges-416x300.jpg 416w" sizes="(max-width: 505px) 100vw, 505px" /></a></dt>
<dd class="wp-caption-dd">                   Vacuum Comparison by Thermocouple Gauges</dd>
</dl>
</div>
<p>The post <a rel="nofollow" href="http://www.instrumentationtoday.com/thermocouple-vacuum-gauge/2011/10/">Thermocouple Vacuum Gauge</a> appeared first on <a rel="nofollow" href="http://www.instrumentationtoday.com">Instrumentation-Electronics</a>.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.instrumentationtoday.com/thermocouple-vacuum-gauge/2011/10/feed/</wfw:commentRss>
		<slash:comments>1</slash:comments>
		</item>
		<item>
		<title>Pirani Gauge</title>
		<link>http://www.instrumentationtoday.com/pirani-gauge/2011/10/</link>
		<comments>http://www.instrumentationtoday.com/pirani-gauge/2011/10/#respond</comments>
		<pubDate>Wed, 05 Oct 2011 04:57:57 +0000</pubDate>
		<dc:creator><![CDATA[John]]></dc:creator>
				<category><![CDATA[Transducers]]></category>
		<category><![CDATA[Sensors]]></category>
		<category><![CDATA[Vacuum Gauge]]></category>

		<guid isPermaLink="false">http://www.instrumentationtoday.com/?p=581</guid>
		<description><![CDATA[<p>A basic pirani gauge consists of a fine wire of tungsten or platinum of about 0.002 cm in diameter. This wire is mounted in a tube and then connected to the system whose vacuum is to be measured. The temperature range is around (7-400) degree Celsius and the heating current is between (10-100) mA.  A [&#8230;]</p>
<p>The post <a rel="nofollow" href="http://www.instrumentationtoday.com/pirani-gauge/2011/10/">Pirani Gauge</a> appeared first on <a rel="nofollow" href="http://www.instrumentationtoday.com">Instrumentation-Electronics</a>.</p>
]]></description>
				<content:encoded><![CDATA[<p style="text-align: justify;">A basic pirani gauge consists of a fine wire of tungsten or platinum of about 0.002 cm in diameter. This wire is mounted in a tube and then connected to the system whose vacuum is to be measured. The temperature range is around (7-400) degree Celsius and the heating current is between (10-100) mA.  A bridge circuit is also used for greater accuracy. The pirani gauge is connected as one arm of the bridge circuit. The figure is shown below. <a title="Vacuum Gauge" href="http://www.instrumentationtoday.com/vacuum-gauge/2011/10/" target="_blank"><span style="text-decoration: underline;"><strong>Vacuum measurement</strong></span></a> is usually taken in three ways.</p>
<ul style="text-align: justify;">
<li>When the pressure changes, there will be a change in current. For this, the voltage V has to be kept constant.</li>
<li>The resistance R2 of the gauge is measured, by keeping the gauge current constant.</li>
<li>The null balance of the bridge circuit is maintained by adjusting the voltage or current. This change is made with the help of a potentiometer and the change brought will be a measure of the pressure produced.</li>
</ul>
<p>You may also like: <a title="McLeod Gauge" href="http://www.instrumentationtoday.com/mcleod-gauge/2011/10/" target="_blank"><span style="text-decoration: underline;"><strong>McLeod Gauge</strong></span></a> and <a title="Pressure Transducer" href="http://www.instrumentationtoday.com/pressure-transducer/2011/09/" target="_blank"><span style="text-decoration: underline;"><strong>Pressure Sensors</strong></span></a></p>
<div class="mceTemp" style="text-align: justify;">
<dl id="attachment_636" class="wp-caption alignnone" style="width: 496px;">
<dt class="wp-caption-dt"><a href="http://www.instrumentationtoday.com/wp-content/uploads/2011/10/Pirani-Gauge.jpg"><img class="size-full wp-image-636" title="Pirani Gauge" src="http://www.instrumentationtoday.com/wp-content/uploads/2011/10/Pirani-Gauge.jpg" alt="Pirani Gauge" width="486" height="416" srcset="http://www.instrumentationtoday.com/wp-content/uploads/2011/10/Pirani-Gauge.jpg 486w, http://www.instrumentationtoday.com/wp-content/uploads/2011/10/Pirani-Gauge-300x256.jpg 300w, http://www.instrumentationtoday.com/wp-content/uploads/2011/10/Pirani-Gauge-350x300.jpg 350w" sizes="(max-width: 486px) 100vw, 486px" /></a></dt>
<dd class="wp-caption-dd">Pirani Gauge</dd>
</dl>
</div>
<p style="text-align: justify;">An additional reference gauge can also be used in the adjacent arm of another pirani gauge, in the bridge circuit. The additional gauge is evacuated and sealed, which helps in the compensaton for variation in ambient temperature. For commercial use, the range of the instrument can be extended from 10<sup>-3</sup> Torr to 1 Torr.</p>
<p>The post <a rel="nofollow" href="http://www.instrumentationtoday.com/pirani-gauge/2011/10/">Pirani Gauge</a> appeared first on <a rel="nofollow" href="http://www.instrumentationtoday.com">Instrumentation-Electronics</a>.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.instrumentationtoday.com/pirani-gauge/2011/10/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>McLeod Gauge</title>
		<link>http://www.instrumentationtoday.com/mcleod-gauge/2011/10/</link>
		<comments>http://www.instrumentationtoday.com/mcleod-gauge/2011/10/#comments</comments>
		<pubDate>Tue, 04 Oct 2011 08:01:55 +0000</pubDate>
		<dc:creator><![CDATA[John]]></dc:creator>
				<category><![CDATA[Transducers]]></category>
		<category><![CDATA[Sensors]]></category>
		<category><![CDATA[Vacuum Gauge]]></category>

		<guid isPermaLink="false">http://www.instrumentationtoday.com/?p=579</guid>
		<description><![CDATA[<p>McLeod Gauge is a vacuum gauge that uses the same principle as that of a manometer. By using the pressure dividing technique, its range can be extended from a value of 10-4 Torr. The basic principle is called the multiple compression technique. It is shown in the figures below. If there are two bulbs A [&#8230;]</p>
<p>The post <a rel="nofollow" href="http://www.instrumentationtoday.com/mcleod-gauge/2011/10/">McLeod Gauge</a> appeared first on <a rel="nofollow" href="http://www.instrumentationtoday.com">Instrumentation-Electronics</a>.</p>
]]></description>
				<content:encoded><![CDATA[<p style="text-align: justify;">McLeod Gauge is a <a title="Vacuum Gauge" href="http://www.instrumentationtoday.com/vacuum-gauge/2011/10/" target="_blank"><span style="text-decoration: underline;"><strong>vacuum gauge</strong></span></a> that uses the same principle as that of a <a title="Manometer" href="http://www.instrumentationtoday.com/manometer/2011/09/" target="_blank"><span style="text-decoration: underline;"><strong>manometer</strong></span></a>. By using the pressure dividing technique, its range can be extended from a value of 10<sup>-4</sup> Torr. The basic principle is called the multiple compression technique. It is shown in the figures below. If there are two bulbs A and B connected with the McLeod and test gauges through capillary tubings, the pressure on the right hand side of the test gauge is very small and the capillary connection between T and bulb B very long, then the flow law can be written as</p>
<p style="text-align: justify;"><em><strong>V.dp2/dt = K.(p1-p2)</strong></em></p>
<p style="text-align: justify;">V- Volume of the bulb</p>
<p style="text-align: justify;">dp2/dt – Pressure Gradient in time between the two elements</p>
<p style="text-align: justify;">K – Flow conductance in the capillary.</p>
<p style="text-align: justify;">As p2 is very small when compared to p1, the flow rate remains practically constant and is proportional to the pressure. This forms the basis of the calibration.</p>
<p style="text-align: justify;">There are many variations of the McLeod Gauge. The basic construction is shown in the figure below.</p>
<div class="mceTemp" style="text-align: justify;">
<dl id="attachment_632" class="wp-caption alignnone" style="width: 477px;">
<dt class="wp-caption-dt"><a href="http://www.instrumentationtoday.com/wp-content/uploads/2011/10/McLeod-Gauge1.jpg"><img class="size-full wp-image-632" title="McLeod Gauge" src="http://www.instrumentationtoday.com/wp-content/uploads/2011/10/McLeod-Gauge1.jpg" alt="McLeod Gauge" width="467" height="531" srcset="http://www.instrumentationtoday.com/wp-content/uploads/2011/10/McLeod-Gauge1.jpg 467w, http://www.instrumentationtoday.com/wp-content/uploads/2011/10/McLeod-Gauge1-263x300.jpg 263w" sizes="(max-width: 467px) 100vw, 467px" /></a></dt>
<dd class="wp-caption-dd">                                            McLeod Gauge</dd>
</dl>
</div>
<p style="text-align: justify;"><strong>Working</strong></p>
<p style="text-align: justify;">The gauge is used to compress a small quantity of low pressure gas to produce a readable large pressure. Bulb B of the gauge is attached to capillary aa’. The mercury level in the gauge is lowered up to l1 by lowering the reservoir, thereby allowing a little process fluid to enter B. By raising the reservoir, the gas is now compressed in the capillary aa’ till mercury rises to the zero mark in the side tube and capillary bb’. The capillary bb’ is required to avoid any error due to capillary.</p>
<p style="text-align: justify;">The McLeod gauge is independent of gas composition. If, however, the gas contains condensable material and during compression it condenses, the reading of the gauge is faulty. The gauge is not capable of continuous reading and the scale is of square law type. For linearizing the scale at comparatively higher pressures, a second volume is introduced as shown in the figure below, where the scale shown is linear.</p>
<div class="mceTemp" style="text-align: justify;">
<dl id="attachment_633" class="wp-caption alignnone" style="width: 481px;">
<dt class="wp-caption-dt"><a href="http://www.instrumentationtoday.com/wp-content/uploads/2011/10/McLeod-Gauge-For-Linear-Scale.jpg"><img class="size-full wp-image-633" title="McLeod Gauge For Linear Scale" src="http://www.instrumentationtoday.com/wp-content/uploads/2011/10/McLeod-Gauge-For-Linear-Scale.jpg" alt="McLeod Gauge For Linear Scale" width="471" height="398" srcset="http://www.instrumentationtoday.com/wp-content/uploads/2011/10/McLeod-Gauge-For-Linear-Scale.jpg 471w, http://www.instrumentationtoday.com/wp-content/uploads/2011/10/McLeod-Gauge-For-Linear-Scale-300x253.jpg 300w, http://www.instrumentationtoday.com/wp-content/uploads/2011/10/McLeod-Gauge-For-Linear-Scale-355x300.jpg 355w" sizes="(max-width: 471px) 100vw, 471px" /></a></dt>
<dd class="wp-caption-dd">                             McLeod Gauge For Linear Scale</dd>
</dl>
</div>
<p>The post <a rel="nofollow" href="http://www.instrumentationtoday.com/mcleod-gauge/2011/10/">McLeod Gauge</a> appeared first on <a rel="nofollow" href="http://www.instrumentationtoday.com">Instrumentation-Electronics</a>.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.instrumentationtoday.com/mcleod-gauge/2011/10/feed/</wfw:commentRss>
		<slash:comments>1</slash:comments>
		</item>
		<item>
		<title>Vacuum Gauge</title>
		<link>http://www.instrumentationtoday.com/vacuum-gauge/2011/10/</link>
		<comments>http://www.instrumentationtoday.com/vacuum-gauge/2011/10/#comments</comments>
		<pubDate>Tue, 04 Oct 2011 06:52:13 +0000</pubDate>
		<dc:creator><![CDATA[John]]></dc:creator>
				<category><![CDATA[Transducers]]></category>
		<category><![CDATA[Sensors]]></category>
		<category><![CDATA[Vacuum Gauge]]></category>

		<guid isPermaLink="false">http://www.instrumentationtoday.com/?p=575</guid>
		<description><![CDATA[<p>For pressure measurement below atmosphere or vacuum, different gauges are available. Manometers and bell gauges can go up to 0.1 Torr. Diaphragm gauges are usable up to a pressure of 10-3 Torr. For pressure below this value, electrical gauges like Pirani or Ionization Gauges are used. Vacuum measurement is broadly classified into Mechanical Type, Thermal [&#8230;]</p>
<p>The post <a rel="nofollow" href="http://www.instrumentationtoday.com/vacuum-gauge/2011/10/">Vacuum Gauge</a> appeared first on <a rel="nofollow" href="http://www.instrumentationtoday.com">Instrumentation-Electronics</a>.</p>
]]></description>
				<content:encoded><![CDATA[<p style="text-align: justify;">For pressure measurement below atmosphere or vacuum, different gauges are available. <a title="Manometer" href="http://www.instrumentationtoday.com/manometer/2011/09/" target="_blank"><span style="text-decoration: underline;"><strong>Manometers</strong></span></a> and <a title="Bell Gauge" href="http://www.instrumentationtoday.com/pressure-transducer/2011/09/#Bell%20Gauge" target="_blank"><span style="text-decoration: underline;"><strong>bell gauges</strong></span></a> can go up to 0.1 Torr. <a title="Diaphragm Pressure Transducer" href="http://www.instrumentationtoday.com/diaphragm-pressure-transducer/2011/09/" target="_blank"><span style="text-decoration: underline;"><strong>Diaphragm gauges</strong></span></a> are usable up to a pressure of 10-3 Torr. For pressure below this value, electrical gauges like Pirani or Ionization Gauges are used. Vacuum measurement is broadly classified into Mechanical Type, Thermal Type, Ionization Type, and Radiation Vacuum Gauge.</p>
<ul style="text-align: justify;">
<li>A standard manometric type mechanical gauge that is used down to 10-4 Torr is the <a title="McLeod Gauge" href="http://www.instrumentationtoday.com/mcleod-gauge/2011/10/" target="_blank"><span style="text-decoration: underline;"><strong>McLeod Gauge</strong></span></a>.</li>
<li>Thermal type vacuum gauge can be further divided into <a title="Pirani Gauge" href="http://www.instrumentationtoday.com/pirani-gauge/2011/10/" target="_blank"><strong><span style="text-decoration: underline;">Pirani Gauge</span></strong></a> and <a title="Thermocouple Vacuum Gauge" href="http://www.instrumentationtoday.com/thermocouple-vacuum-gauge/2011/10/" target="_blank"><strong><span style="text-decoration: underline;">Thermocouple Type Vacuum Gauge</span></strong></a>.</li>
<li>Ionization Gauge can be divided into <a title="Ionization Gauge – Hot Cathode Type" href="http://www.instrumentationtoday.com/ionization-gauge-hot-cathode-type/2012/01/" target="_blank"><strong><span style="text-decoration: underline;">Hot Cathode Type</span></strong></a> and <a title="Ionization Gauge – Cold Cathode Type" href="http://www.instrumentationtoday.com/ionization-gauge-cold-cathode-type/2012/01/" target="_blank"><strong><span style="text-decoration: underline;">Cold Cathode Type</span></strong></a>.</li>
<li>One type of radiation gauge called <a title="Alphatron Vacuum Gauge" href="http://www.instrumentationtoday.com/alphatron-vacuum-gauge/2011/10/" target="_blank"><strong><span style="text-decoration: underline;">Alphatron</span></strong></a> is explained.</li>
<li>Other type of vacuum gauge includes the <a title="Quartz Reference Vacuum Gauge" href="http://www.instrumentationtoday.com/quartz-reference-vacuum-gauge/2011/10/" target="_blank"><strong><span style="text-decoration: underline;">Quartz Reference Vacuum Gauge</span></strong></a>.</li>
</ul>
<p style="text-align: justify;"><strong>Thermal Types</strong></p>
<p style="text-align: justify;">The heat conductivity of gases is independent of its pressure, at normal pressure. But, heat conductivity starts falling as the pressure is lowered t 10 Torr and below. The reason behind this is less collision between gas molecules within the wall and also their small number in a specific volume. The energy is carried to the walls of the container due to this collision. Thus, lesser number of molecules will be available to take the heat away from the source.</p>
<p style="text-align: justify;">At low pressures, the heat loss that occurs from a hot wire mounted in a glass or metal tube is due to the following factors.</p>
<ul style="text-align: justify;">
<li>Convection</li>
<li>Conduction through the lead mines</li>
<li>Radiation</li>
<li>Conduction in the gas</li>
</ul>
<p style="text-align: justify;">Out of these, convection is comparatively negligible. A new clear wire has a small surface emissivity and is god for producing high temperature at low gas pressures. Due to oxidation and carbonization, the surface tends to deteriorate. This causes error of the device at low pressure ranges.</p>
<p>The post <a rel="nofollow" href="http://www.instrumentationtoday.com/vacuum-gauge/2011/10/">Vacuum Gauge</a> appeared first on <a rel="nofollow" href="http://www.instrumentationtoday.com">Instrumentation-Electronics</a>.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.instrumentationtoday.com/vacuum-gauge/2011/10/feed/</wfw:commentRss>
		<slash:comments>1</slash:comments>
		</item>
	</channel>
</rss>

<!--
Performance optimized by W3 Total Cache. Learn more: https://www.w3-edge.com/products/

Page Caching using disk: enhanced 

Served from: www.instrumentationtoday.com @ 2021-08-02 20:18:03 by W3 Total Cache
-->